Sale!

Covidien Capnostream 20p Capnograph

Original price was: $273.75.Current price is: $68.44.

SKU: SWIAY681818 Category:

Description

Covidien Capnostream20p Capnograph

This is a refurbished Capnograph that monitors ETCO2 and SPO2. It will arrive “patient ready” with a 1yr warranty.

Capnostream20p Bedside Patient Monitor Features

Dual parameter monitor

  • – Supports current standards of care by providing etCO2and SpO2measurements.

Smart Alarm ManagementIntegrated Algorithms1-2

– The Capnostream20p patient monitor witicrostreamincludes Smart Alarm ManagementIntegrated Algorithms, a suite of algorithms proven to reduce alarms and simplify the use of patient monitoring to enhance patient safety and improve clinical efficiency.

Smart Breath Detection

  • – Screens out low amplitude ‘non-breath’ etCO2excursions like, talking, crying or snoring.

Smart Alarm for Respiratory Analysis(SARA)

  • – Reduces clinically insignificant alarms.

Nellcor™ SatSeconds

  • – Alerts clinicians to clinically significant changes in pulse oximetry.

Integrated Pulmonary IndexAlgorithm (IPI )

  • – IPI algorithm presents one value that demonstrates real-time respiratory status based on etCO2, RR, PR and SpO2.††

Apnea-Sat AlertAlgorithm (ASA )

  • – Tracks and reports apneas per hour and oxygen desaturation index, and provides the data in trend reports.

Connectivity

  • – Compatible with central monitoring systems and interfaces with nurse call systems and electronic medical records.

Internal printer

  • – Provides convenient bedside documentation.

†SARA evaluates the stability of the detected breath-to-breath intervals and adjusts (adapts) the measurement period accordingly, thus averaging out noise and transient fluctuations when required, providing a more realistic respiratory rate.

††SpO2 data from host required.

†††Apnea-Sat Alert is FDA cleared for adults 22 years of age or older.

1. ECRI Institute. The Hazards of Alarm Overload: Keeping Excessive Physiologic Monitoring Alarms from Impeding Care. ECRI Guidance Ale, March 2007.

2. Hockman S, Glembot T, Niebel K. Comparison of capnography derived respiratory rate alarm frequency using the SARA algorithm versus an established nonadaptive respiratory rate alarm management algorithm in bariatric surgical patients.Resp Care (Open Forum Abstracts). 2009;12

Capnostream20p Bedside Patient Monitor Specifications

Specification Overview:

General characteristics

Unit dimensions:

167 mm. (h) x 220 mm. (w) x 192 mm. (d)

(6.6 in. (h) x 8.7 in. (w) x 7.6 in. (d))

Unit weight:

3.6 kg.

7.94 lb.

Packaged dimensions:

315 mm. (h) x 340 mm. (w) x 285 mm. (d)

12.4 in. (h) x 13.4 in. (w) x 11.2 in. (d)

Power supply

Input Voltage 100-240 V, 50/60 Hz, ± 10%.

Microstream® capnography

• Units: mmHg, kPa or Vol%.

• Measurement range etCO2, FiCO20-150 mmHg.

• Respiratory Rate 0 bpm-150 bpm.

• Resolution 1 mmHg.

• Accuracy (±SD) etCO2, FiCO20-38 mmHg ± 2 mmHg. 39-150 mmHg ± (5% of reading + 0.08% for every 1 mmHg above 38 mmHg).

• Respiratory rate: 0-70 bpm ±1 bpm, 71-120 bpm ±2 bpm, 121-150 bpm ±3 bpm.

• Flow rate 50 ml/minute, flow measured by volume.

• Waveform sampling 50 millisecond intervals.

• Response time 2.95 second (typical).

• Initialization time 40 second (typical).

• Calibration interval Initial calibration after 1,200 operating hours, then annually or after 4,000 operating hours, whichever comes first.

Nellcorpulse oximetry

• Measurement range 0-100%.

• Accuracy

Adult mode:

o SpO2range 70%-100% ± 2 digits.

o SpO2range 0-69% unspecified.

Neonate mode:

o SpO2range 70%-100% ± 3 digits.

o SpO2range 0-69% unspecified.

• Pulse rate

o Range: 20-250 BPM.

o Accuracy: ± 3 BPM.

o Sat Sec Range: 10, 25, 50, 100.